Konica Minolta FD-7 Spectrophotometer – Spectrodensitometer

  • 16. January 2024 6:18
  • Germany
  • 142 views
Popular
Konica Minolta FD-7 Spectrophotometer – Spectrodensitometer
Konica Minolta FD-7 Spectrophotometer – Spectrodensitometer
Konica Minolta FD-7 Spectrophotometer – Spectrodensitometer
Konica Minolta FD-7 Spectrophotometer – Spectrodensitometer
Konica Minolta FD-7 Spectrophotometer – Spectrodensitometer
Konica Minolta FD-7 Spectrophotometer – Spectrodensitometer
Konica Minolta FD-7 Spectrophotometer – Spectrodensitometer
Konica Minolta FD-7 Spectrophotometer – Spectrodensitometer
Konica Minolta FD-7 Spectrophotometer – Spectrodensitometer
Konica Minolta FD-7 Spectrophotometer – Spectrodensitometer

Description

The Konica Minolta FD-7 also measures in the M1 measurement mode as a scan measurement in the strip mode in one pass.
It is supported by EFI Fiery XF from EFI Fiery XF 5.0, by basICColor Catch 4, by EFI Color Profiler
(optional for the EFI hardware Fierys) and of course from Konica Minolta’s own software.

Technical data:

  • Illumination / viewing system:45°a:0° (annular illumination / perpendicular viewing) (*1);
    complies with CIE 15:2004, ISO 7724-1, DIN 5033-7, ASTM E 1164 and JIS 8722 Measurement conditions for
    Body colors
  • Monochromator: concave grating
  • Wavelength range: reflection: 380 to 730 nm; illuminance: 360 to 730 nm
  • Wavelength resolution: 10 nm
  • Half-value bandwidth: approx. 10 nm
  • Measuring field: Ø 3.5mm
  • Light source: LED
  • Measuring range: color density: 0.0 density units; reflectance 0 to 150% illuminance 0 to 9990 lux.
  • Repeatability: Color density: s0.01 density units
  • Colorimetric: Colorimetric: within sDE00 0.05 referred to the white standard at 30 measurements
    in 10 seconds interval after white calibration)
  • Device match: Within DE00 0.03 (mean value related to 12 BCRA II color tiles in comparison
    to the data obtained with the master instrument under the Konica Minolta test conditions).
  • Measuring time: approx. 1.4 s (single measurement reflection)
  • Display types: colorimetric data, color difference values, color density values, color density difference values,
    PASS/FAIL evaluation, dot gain, color acceptance, illuminance, color temperature
  • Measurement conditions: According to ISO 13655: Measuring condition MO (CIE illuminant A), M1 (CIE illuminant D50),
    M2 (with UV blocking filter), user illuminant
  • Light modes: A, C, D50, ID50, D65, ID65, F2, F6, F7, F8, F9, F10, F11, F12, user light mode
  • Included in delivery: Spectraldensitometer FD-7, USB data cable, pouch, measuring aperture, ruler, protection glass, polarization filter, AC adapter, software basiCColor Catch